NOISE POLLUTION STUDIES OF PORT HARCOURT REFINERY, PART - 1: THE SPATIAL VARIATIONS AND DISPERSION

Authors

  • DR. IFY L. NWAOGAZIE Department of Civil Engineering, University of Port Harcourt. P.M.B. 5323, Port Harcourt. Author
  • DR. I. C. OWATE Department of Physics, University of Port Harcourt. P.M.B. 5323, Port Harcourt. Author

Keywords:

Noise pollution, Noise dispersion rates, The positive aspect of noise

Abstract

The noise pollution studies undertaken at the Port Harcourt Refining Company, PHRC, Nigeria in 1993 were performed in two stages. The first stage which forms the basis of this paper involved field surveys and identification of noise sources, spot readings of noise levels at 1.0 meter from source and spatial measurements along selected routes for estimate of dispersion rates. About 300 noise sources were identified and subsequently grouped in terms of equipment type as: 47% air cooler/fans, 37% pumps, 6% compressors and 10% others. Spatial measurements covered 2.9 kilometers of distance and 94 point locations for spot readings. Analysis of data revealed that two average rates of noise dispersion of 0.052 and 0.062 dB (A) per meter are representative of the study area. Generated noise levels within PHRC are well dispersed. Also, three broad classifications of the "status conditions" of the operating equipment performance are possible based on the concept of the "positive aspects of noise". The first, second and third classes are those wherein the age and/or use affect equipment performance minimally, reasonably and adversely, respectively. And a fault is likely for the second and third classes.

Downloads

Published

1995-12-22