A study has been made of the sources and detection of air pollutants in engine test laboratories during performance tests, cubicles for exhaust gas analyser or calibration gas bottles and automobile workshop during engine tuning process. Engine design, operational mode, calibration gas concentration and laboratory ventilation were identified as variable factors that can influence the concentration of pollutants in the test environment. The investigation covered the determination of carbon monoxide (CO), nitrous fumes - NO, (nitric oxide and nitrogen dioxide), and diesel odour intensity in these working environments.

The effects of pollutants on test operators, inconsistency of test results, inadequate ventilation in the laboratory and the existence of pollutants in automobile workshop are also discussed. Generally, it was observed that concentration levels of CO and NO, in the laboratory, gas bottle cubicles and automobile workshop vary during the test period. High concentration levels occurred immediately after calibration, during long idling and high speed and load operation when ventilation was inadequate.

The ambient air quality standard as set by the World Health Organisation (WHO) in 1987 for CO and nitric dioxide (NO₂) for one hour exposure are compared with measured values. When ventilation was adequate, the concentration levels of the pollutants were lower than the set values.